Locations Technical Library Compliance Speak Up EN
NJORD United States
NJORD
HomeWhat we trade
Oil & Petroleum
Crude OilGas CondensateVacuum Gasoil & LCOPetroleum CokeCarbon Black Feedstock
Gas & Power
LPGLNGMethanolHydrogen
Refined Products
GasolineNaphthaDieselGasoilAviation Fuel & KeroseneMarine Fuels & BunkersBase Oils & AdditivesBitumenCertified Components
Metals & Minerals
Precious MetalsBase & Battery MetalsIron Ore & SteelApatite Concentrate
Agriculture
GrainsOilseedsSugarCoffeeCocoa & CottonEdible Oils & Dairy
Fertilisers & Nutrients
NitrogenAutomotive Urea (AdBlue® / DEF)SulphurPhosphatePotashNPK & ComplexFeed Additives
Chemicals
Mining ChemicalsMineral AcidsSalts & GasesAlkylates & ParaffinsSulphur
Industrial Materials
Concrete RollFormwork Girder H20SoftwoodHardwoodEngineered WoodIndustrial WoodWood-Derived Products
Company
Who we areLogisticsFinancingSustainabilityCareersOnboardingTechnical LibraryContact

Engineered wood

Panels fail at the glue line, and the glue line is the one thing you cannot see.

Plywood, MDF, OSB and particleboard are bought on thickness and price and returned on bonding class and formaldehyde emission. Two panels of identical dimension can be built for entirely different service conditions, and the difference is invisible until the first wet week.

The programme

Four panel families, and one beam.

Panels from European production, in the grades and thicknesses the order calls for, with the certification that lets them be used where they are going rather than a generic mill certificate.

Plywood
Birch and combi construction, standard and film-faced, plus flooring grades for transport bodies and interiors, and LNG cargo-containment insulation grade. Thicknesses, ply counts and face grades to order.
MDF
Medium-density fibreboard for furniture, joinery and interior fit-out. Standard, moisture-resistant and fire-retardant types, raw or faced.
OSB
Oriented strand board in the four EN 300 grades, for sheathing, decking, packaging and site use.
Particleboard
Chipboard in the EN 312 type range, raw and melamine-faced, for furniture and interior applications.
H20 formwork girders
Glued timber I-beams, plywood web and softwood flanges, to EN 13377 — a full technical page of its own: Formwork Girder H20.

Panels are bought to your order rather than held in stock, in the construction, grade, thickness and facing specified. Nothing here is a stock list, so the specification is settled before production rather than matched to what happens to be available.

The two numbers that matter

Bonding class and service class are different things, and both get quoted as “WBP”.

One describes the glue's resistance to water in a laboratory test. The other describes the conditions the finished panel is fit to live in. “Waterproof” and “exterior” are marketing words that map onto neither precisely, and they are the words in most enquiries.

StandardClassWhat it means
EN 314-2
bonding quality of the glue line
Class 1Dry conditions. Interior use, no risk of wetting.
Class 2Humid conditions. Protected exterior, short-term weather exposure.
Class 3Exterior conditions. The test regime includes boiling; this is the class behind the phrase “WBP”.
EN 636
plywood use class
EN 636-1Dry conditions.
EN 636-2Humid conditions.
EN 636-3Exterior conditions. This is the class specified for formwork and for structural exterior use.
EN 13986The harmonised standard for wood-based panels used in construction. Panels going into a building need CE marking and a declaration of performance under it, covering reaction to fire, formaldehyde class, mechanical properties and biological durability.
A Class 3 glue line does not make a panel an exterior panel. The bond can survive boiling while the veneers behind it swell, check and delaminate at the edges, because durability of the wood and durability of the adhesive are separate properties. Exterior service needs the use class, the edge sealing and the coating specified together — and an untreated exposed edge is where every plywood failure in a hot, humid climate begins.

Plywood

Four things a plywood order needs beyond the thickness.

Thickness and sheet size are the easy part. What separates two quotations on “18 mm birch” is usually the construction, the face grade, the tolerance and the film.

Construction — birch or combi
All-birch panels have birch throughout the core and the faces; combi panels have birch faces with a softwood core, or alternating layers. Combi is lighter and cheaper, and it is not the same panel — screw holding, edge quality, stiffness and impact resistance all differ. An enquiry for “birch plywood” that is answered with combi is not being cheated, it is being answered loosely, so name the construction.
Face grade
Face and back are graded separately and quoted as a pair — a B/BB panel has a better face than back. The grade governs patches, plugs, colour and open defects, and it is the largest single price step in the panel.
Film-faced, for formwork
Phenolic film on both faces, typically in the 120–220 g/m² range, with the film weight governing the number of pours the panel will give and the finish it leaves on the concrete. Edges sealed at the mill; every cut edge on site has to be resealed by the user or the panel takes water through it. Reuse cycles quoted by a supplier assume the edges are maintained — and on most sites they are not.
Thickness tolerance and sanding
Sanded, unsanded or calibrated. Where the panel goes into a machine-fed process or a laminated assembly, the tolerance matters more than the nominal thickness, and it should be a line in the order.
LNG cargo-containment grade
Insulation plywood for membrane containment systems is a qualified product within a qualified supply chain. Approval sits with the containment-system licensor and the yard's quality regime, not with a merchant, and we will say plainly what we can and cannot arrange rather than imply an approval we do not hold. Enquiries here are handled as a project, with the approval position established first.

Boards

MDF, OSB and particleboard — the type number is the specification.

Each of these families is defined by a type range in its own standard, and the type sets the load-bearing capability and the humidity the panel can live in. A board ordered without a type number is a board ordered on price alone.

PanelStandardType rangeThe distinction that matters
OSBEN 300OSB/1 to OSB/4OSB/1 is interior, non-load-bearing. OSB/2 is load-bearing in dry conditions. OSB/3 is load-bearing in humid conditions — the general construction grade. OSB/4 is heavy-duty load-bearing in humid conditions. Substituting OSB/2 for OSB/3 on a humid site is the classic false economy.
ParticleboardEN 312P1 to P7P1 and P2 are interior, non-load-bearing — P2 being the furniture board. P3 is non-load-bearing in humid conditions; P5 is load-bearing in humid conditions; P7 is heavy-duty. Furniture board in a wet application swells irreversibly and does not recover.
MDFEN 622-5MDF, MDF.H, MDF.LA and othersStandard, humid-resistant and load-bearing variants. Fire-retardant grades are a separate specification with their own reaction-to-fire classification, and the classification travels with the panel, not with the brochure.

Faced boards — melamine, foil, veneer — carry the facing specification in addition to the board type: décor reference, finish, and whether the facing is on one or both sides. A décor is a manufacturer's reference and it is not interchangeable between producers, so a repeat order matched to an existing installation has to name the original producer and reference.

Emissions

Formaldehyde class, and which market you are shipping into.

Wood-based panels bonded with amino resins emit formaldehyde, and the permitted level is regulated differently in different markets. This is the specification most often left out of an enquiry and most often the reason a shipment is rejected at the destination.

European classes
E1 is the general European class, declared under EN 13986 and tested by the chamber method of EN 717-1. Lower-emission products are marketed as E0 or as fractions of the E1 limit — those are producer designations rather than a separate harmonised class, so the number and the test method both have to be stated.
North American requirements
CARB Phase 2 and the federal TSCA Title VI rule set their own limits and require third-party certification and labelling. A panel that is compliant in Europe is not automatically compliant for a US or Canadian destination, and the certification cannot be added after production.
Project specifications
Green-building schemes frequently specify emission levels tighter than the regulatory minimum. If your project is chasing a rating, the emission class belongs in the enquiry, because it changes the resin system and therefore the producer.

We state the class and the test method on the offer, and the certificate travels with the parcel. Where a destination requires third-party certification we confirm the producer holds it before quoting rather than after.

Straight answer

What it is not, said before you find out.

“Waterproof” is not a class and we will not write it into an offer
Bonding class to EN 314-2 and use class to EN 636 are the two things that can be specified and tested. Anything else is a description.
Film-faced reuse figures assume maintenance you will not do
Cut edges resealed after every cut, panels cleaned rather than scraped, stacked flat and dry. The published cycle count is an upper bound achieved under those conditions, and site reality takes a large bite out of it.
Birch and combi are not the same panel
They differ in weight, stiffness, screw holding and edge quality. Name the construction in the enquiry or you are letting the cheapest interpretation win.
We do not hold LNG containment approvals
Approval for cargo-containment insulation material sits with the system licensor and the yard. We will tell you what is arrangeable and what is not, and we will not imply a qualification we do not have.
A décor match across producers does not exist
Faced board references belong to the producer. Matching an existing installation means going back to the original producer and reference, and where that producer has discontinued the décor there is no equivalent, only a near miss.
Panels are damaged in handling more often than in service
Corner and edge damage, moisture pickup through unsealed edges, and distortion from being stacked on an uneven base. Packing and stacking instructions are part of the specification, and we would rather over-specify the packing than argue about the arrival condition.

How to specify

Nine lines, and we can price it properly.

1 · Panel family and type
Plywood, MDF, OSB or particleboard — with the type number where the standard has one: OSB/3, P5, MDF.H.
2 · Bonding and use class
EN 314-2 class and, for plywood, the EN 636 use class.
3 · Construction
For plywood: all-birch or combi, ply count, and face and back grades as a pair.
4 · Dimensions and tolerance
Sheet size, thickness, and the thickness tolerance where the panel feeds a machine or a laminated assembly. Sanded, unsanded or calibrated.
5 · Surface
Raw, film-faced with the film weight, melamine or foil-faced with the décor reference, or veneered.
6 · Formaldehyde class
E1, a lower producer designation, or CARB Phase 2 / TSCA Title VI for a North American destination.
7 · Reaction to fire
Where the panel is going into a building, the required Euroclass — which may mean a fire-retardant grade rather than a coating applied later.
8 · Certification
CE marking and declaration of performance to EN 13986 where the use is structural or in construction; FSC or PEFC where required.
9 · Destination, quantity and timing
Port and country, volume per thickness, and whether this is one parcel or a programme.

Inspection

What we check, and what travels with the goods.

Type testing and factory production control
Bonding quality to EN 314-2, panel properties and CE marking with the declaration of performance to EN 13986, formaldehyde emission by the declared test method, and the producer's factory production control certification. Reports supplied with the first order and on any change of production specification.
Pre-shipment inspection
Where the buyer requires it, an agency appointed for the consignment — SGS, Bureau Veritas or Intertek — instructed jointly, verifying panel count, sheet dimensions, thickness across the parcel, face grade against the specification, film weight where film-faced, edge sealing, marking, pallet condition and moisture protection.
Condition on arrival
Wrapping intact, edges undamaged, no water staining, panels flat and stacked on a level base. Panels absorb moisture through unsealed edges faster than through faces, so edge condition on arrival is the reading that predicts service life.
Documentation per shipment
Declaration of performance and CE marking where applicable; bonding class and use class certificates; formaldehyde emission certificate naming the test method, plus CARB or TSCA certification for a North American destination; reaction-to-fire classification report where a fire grade is specified; FSC or PEFC certificate and transfer document where sold certified; packing list with pallet numbers, sheet counts and dimensions; certificate of origin naming the producing mill; bill of lading; and the inspection report where an agency is appointed.

Related: Formwork Girder H20 · Softwood · Wood-Derived Products · Industrial Materials

Enquiries

Every enquiry is answered by the desk that handles it.

Send the product, quantity, delivery basis, destination and timing. We revert with availability, an indication and the documentation that accompanies it. Specifications are released once we know who we are speaking with.